- General Information
- Manufacturer
- Tripp Lite by Eaton
- Manufacturer Website Address
- https://tripplite.eaton.com/
- Brand Name
- Tripp Lite by Eaton
- Product Type
- UPS/Network Management/PDU Kit
Ship in Days, Not Weeks
Tripp Lite's EdgeReady™ micro data centers ship three business days after order receipt, assembled and tested. 40 base configurations are available for immediate order, or Tripp Lite's solutions team can customize every aspect of any base configuration to match your specific application. Customized solutions ship in as little as five business days.
Protect Edge Computing
Convenient and cost-effective EdgeReady™ micro data centers protect edge computing servers, storage and network hardware in locations where dedicated IT space is unavailable. Sites like branch offices, banks, retail locations, cell towers and factories often have little or no access to on-site IT staff, but they still require exceptional uptime for edge computing. Micro data centers require minimal space and support, yet provide availability comparable to a traditional data center.
Integrate Key Components
Base configurations combine a rack enclosure, UPS system, network management card, environmental/security sensor, power distribution unit (PDU), downloadable network management software, passive cooling and optional active cooling.
Save Time and Reduce Costs
Preconfigured IT infrastructure accelerates and standardizes installations for quick, easy, repeatable deployments and maintenance. Experienced solution experts design, validate, assemble and test solutions in a controlled environment to simplify orders, prevent configuration errors and reduce field costs. Reinforced shock pallets and torqued fittings stabilize shipment and support re-shipment from an intermediary configuration site.
Target Specific Applications
Tripp Lite offers 40 base configurations, and you can customize any model for your application. Options include active cooling, extended runtime, KVM switches, console servers, added security, airflow management, cable managers, power cords, network cables and patch panels. You can also upgrade the base PDU, rack or UPS.
Power Critical Systems
Two SmartOnline® UPS systems configured for N+N redundancy provide voltage- and frequency-independent (VFI) operation, expandable battery backup, zero transfer time and pure sine wave output. On-line double conversion isolates equipment from blackouts, brownouts, overvoltages, transients, surges, line noise, harmonic distortion, electrical impulses and frequency variations to prevent damage, downtime and data loss. Included battery capacity outlasts most power problems, and optional battery packs increase runtime. Two metered PDUs plug into the UPS systems to provide numerous outlets and digital current metering. Optional switched PDUs add remote current monitoring, threshold notifications and outlet control.
Manage from Any Location
A network management card provides monitoring, control and alerts via SNMP, Web, SSH or telnet. An environmental sensor monitors temperature, humidity and digital inputs. Free PowerAlert® Network Management System manages up to 250 units, or you can use your SNMP-compatible software of choice. Additional options include network-accessible KVM switches and console servers with fail-safe remote access.
Secure Equipment and Data
A PCI-compliant steel cabinet with EIA-standard mounting rails secures rack-mounted IT equipment. Doors and side panels lock to prevent unauthorized access, and an optional door-monitoring kit enables remote intrusion detection.
- Warranty
- Limited Warranty
- 2 Year
- Miscellaneous
- Additional Information
OVERVIEW
UPC Code 037332247186
Rack Type Floor-Standing
UPS Type On-Line
PDU TypeMeteredPOWER
Output Power Capacity (kVA) 10
Output Power Capacity (Amps) 43.2
Output Power Capacity (kW) 9
Site Power Required (2) 208/240V, 60A or 230V, 63A, 50/60 Hz (2 Separate Circuits)
Site Outlet Required (2) Hardwire (208/240V 60A L1-L2-G or 230V 63A L-N-G)
N+N Redundancy YesCOOLING
Cooling Type Passive
Cooling Type Details See Components List for active cooling optionsOUTPUT
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Usable Outlets (UPS and PDU) (64) C13; (22) C19INPUT
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
Input Phase Single-Phase
Input Plug Type Hard-wireBATTERY
Full Load Runtime (min.) 4.3 min.
Half Load Runtime (min.) 12 min.
Expandable Runtime YesPHYSICAL
Maximum Device Depth (in.) 37
Rack Height 42U
Usable Rack Space 30U
Total Weight Capacity (lbs.) 3000
Usable Weight Capacity (lbs.) 2262
Unit Dimensions (hwd / in.) 78.5 x 23.63 x 43
Shipping Form Factor Assembled/Tested Unit
Unit Weight (lbs.) 738ENVIRONMENTAL
Environmental Sensor E2MTHDICOMMUNICATIONS
Network Management Cards (2) WEBCARDLXSPECIAL FEATURES
High Availability UPS Features N+N Redundancy; On-Line (VFI) Operation; Auto Bypass; Battery Backup; Hot swappable batteries; Hot swappable UPS power module
Acoustic Noise Suppression No
- Package Contents
- SR42UB Premium Rack Enclosure
- 2 x SU10000RT3UG UPS Systems
- 2 x WEBCARDLX Network Management Cards
- E2MTHDI Environmental Sensor
- 2 x PDUMV20HV Metered PDUs
- 2 x P036-006 AC Input Cords
- Owner's Manuals
- Environmentally Friendly
- Yes
- Environmental Compliance
- Restriction of Hazardous Substances (RoHS)
- Country of Origin
- China